Benefits
- Fast installation and removal, without concrete curing time
- Reuse of the system at multiple points on the same project
- Lower waste generation and smaller operational footprint
- Early release of the tested area
Reaction system with helical anchors installed and removed within the same working day, replacing conventional reaction piles.
Request a proposalIn conventional static load testing, reaction is obtained with piles installed solely for that purpose and left abandoned in the ground. The SAP system replaces those elements with helical anchors that are installed, carry the load during the test and are then removed.
The result is a direct reduction in schedule, in concrete and steel consumption, and in interference with the rest of the project.

Inmobiliario
Minería
Energía
Industrial
Infraestructura
Saneamiento
Logística
Petróleo y gas
Agroindustria
A team of specialist engineers with a combined 242 years of experience in geotechnics.
We have a structure specialized in foundation quality control, the largest technical team in the sector and more than 60 years of tradition from Grupo Gontijo.
We mobilize proprietary equipment and instrumentation for projects in any country in Latin America.
Calibrated instrumentation and rigorous maintenance across the entire fleet.
Dedicated geotechnical engineers, from planning through to the report.
The experience of Grupo Gontijo, since 1965, applied to every test.
Technical interpretation and recommendations applicable to the project.
Digital record of parameters and complete traceability of the test.
Direct measurement of a deep foundation load capacity through the gradual application of load and the recording of settlement at each stage.
Learn more →The same static test, with strain gauges along the shaft to separate the lateral friction of each soil layer from the end bearing resistance.
Learn more →Controlled hammer blows with force and velocity measurement on the pile, interpreted through wave equation theory.
Learn more →Bidirectional load cell installed inside the pile that applies load simultaneously upward and downward, without a reaction structure at the surface.
Learn more →Low strain test that evaluates shaft continuity and estimates pile length from the reflection of the stress wave.
Learn more →Geoteste proprietary system for applying blows in dynamic testing, with remote actuation and digital recording of every parameter.
Learn more →Rely on someone who knows the subject.
Talk now with a specialist and request a technical proposal tailored to your project.
Talk to an engineer